Course Content
A | INTRODUCTION (open access)
B | BIBLIOGRAPHY
-
Bibliography
-
Applicable standards
10:01 -
Normal operating conditions according to IEC 60076-1
13:08
C | FUNCTIONS, TECHNOLOGIES AND TYPES
-
04:25
-
Q-TDP050
D | PHYSICS
-
06:12
-
Assigned power, voltages and currents
07:48 -
Transformation ratio
03:07 -
Connection and phase displacement symbols
29:22 -
Short-circuit voltage
06:13 -
Transformer losses
-
Internal voltage drop
-
Insulation system and temperature limits
-
Climatic, Environmental and Fire behaviour classes
09:13 -
Normal, standby and parallel modes
-
Noise, vibrations and soundproofing
06:18 -
Q-TDP100
E | PROTECTION
-
Protections against internal faults
-
Protections against external faults
-
Operational protections
-
HV automation systems
-
Surge protection
-
Protective equipment
-
Q-TDP200
F | COMPONENTS AND ACCESSORIES
-
Magnetic core
-
Windings
-
Connections (terminals, bushings, bus ducts)
-
Dry-type transformers | Windings insulation
-
Dry-type transformers | Cooling systems
-
Dry-type transformers | Protection enclosure
-
Dry-type transformers | Windings temperature
-
Dry-type transformers | De-Energized Tap Changer (DETC)
-
Oil transformers | Tank types
17:59 -
Oil transformers | Conservator, membrane, breather
-
Oil transformers | Winding insulation
-
Oil transformers | Oils
15:38 -
15:30
-
Oil transformers | Oil thermometer
-
Oil transformers | Oil level indicator
-
Oil transformers | Cooling system
-
Oil transformers | Windings temperature indicator
-
Oil transformers | Pressure relief valve
-
Oil transformers | Buchholz relay and oil check valve
-
Oil transformers | DGPT2 or DMCR
-
Oil transformers | Valve system and valve plate
-
Oil transformers | De-Energized Tap Changer (DETC)
-
Oil transformers | On load Tap Changer (OLTC)
-
Oil transformers | Marshalling kiosk
-
Oil transformers | Painting
-
Rating plates
17:23 -
Current transformers
-
Earth terminals
-
Support, insulation, hauling or rolling accessories
-
Q-TDP300
G | FEEDBACK
-
Large single-phase transformers
-
Copper or aluminium windings
-
High-voltage tertiary windings
-
Q-TDP400
H | FACTORY INSPECTION AND ACCEPTANCE TESTS
-
Dry-type transformers | Manufacturing Quality Plan
-
Oil transformers | Manufacturing quality plan
-
02:50
-
Dry-type transformers | Routine tests
-
Dry-type transformers | Type tests
-
Dry-type transformers | Special tests
-
Oil transformers | Routine tests
-
Factory acceptance
-
Oil transformers | Type tests
-
Oil transformers | Special tests
-
Q-TDP500
I | TRANSPORT
-
General information
-
Specialised equipment for transporting transformers
-
Oil drums (transport, storage)
-
Special transport
-
Q-TDP600
J | SITE INSTALLATION
-
Oil transformers | Loge transformateur
-
Oil transformers | Bac de rétention d’huile
-
Oil transformers | Oil-water separator
-
Oil transformers | Oil collection pit
-
Oil transformers | Site erection
-
Oil transformers | Fire detection & protection
-
Dry-type transformers | Site erection
-
Dry-type transformers | Fire detection & protection
-
Q-TDP700
K | COMMISSIONING AND MAINTENANCE
-
Oil processing machine
-
Oil transformers | Site tests
-
Oil transformers | Maintenance
-
Dry-type transformers | Site tests
-
Dry-type transformers | Maintenance
-
Q-TDP800
L | TOOLBOX
-
Template | Dry-type transformers | Technical specification
-
Template | Dry-type transformers | Datasheet
-
Template | Dry-type transformers | List of supplier documents
-
Template | Dry-type transformers | Manufacturing quality plan
-
Template | Dry-type transformers | Factory acceptance report
-
Template | Oil transformers | Technical specification
-
Template | Oil transformers | Datasheet
-
Template | Oil transformers | List of supplier documents
-
Template | Oil transformers | Manufacturing quality plan
-
Template | Oil transformer | Factory acceptance test report
-
Tool | Calculation sheet | Capitalised transformer cost
-
Tool | Calculation sheet | Efficiency and internal voltage drop
-
Q-TDP900
FINAL ASSESSMENT
-
TDP final assessment